High Pressure tube leakage.
Recently
the failures of Diesel locos due to crack in HP tubes have been observed.
Drivers were unable to cut off fuel supply by blocking control rack of affected
FIP.
HP
tubes breakages are caused due to excess vibration, crack, use of unapproved
make HP tube etc.
Action to be taken:
Maintenance of HP tube
1.
Only HP tubes of approved make are to be used,
other HP tubes should be weeded out.
2.
DPT testing of HP tube should be conducted in
section itself during M24. In situ testing during M12
should be carried out.
3.
Handling of HP tubes must be done extremely
carefully as slight dent during handling/transportation becomes a stress notch
point for propagation of crack. Suitable HP tube carrier and storage rack
(wooden/rubber/plastic) should be developed.
4.
Profile checking & high pressure testing should
be carried out in testing gadget in section itself.
5.
All HP tubes above 10 yrs. of age should be weeded
out from main line locos, these tubes after testing can be fitted in locos
working in inferior service.
6.
Grommets must be renewed during M24.
Condition of Grommet must be checked in every schedule & perished Grommets
should be replaced.
7.
Vibration measurement of HP tube should be carried
out in M2 and above schedule. All locations showing higher vibration
should be attended & vibration level should be brought down.
Checking fuel delivery at zero rack travel
Blanking
of FIP in case of HP tube leakage should be done en-route.
All FIPs should be tested in section for fuel
leakage when control rack is locked at zero by pump latch. It should be ensured
that there is no HSD leakage when rack is locked at zero. This is an
important fire prevention criterion.
“Move the control rack towards stop position and engage the latch with
the slot provided in the control rack. Run the test bench at 200 RPM. There
should be no delivery. ” (Ref- Page No. 11 & 12 of Instructions Manual on
FIP).
It will ensure that even in case of mid-section HP
tube breakage, drivers are able to complete the trip and failed HP tubes can be
changed at Trouble shooting points.